About the Program
ABBYY FlexiCapture is a highly scalable platform for intelligent data and document capture which can be successfully used to extract data from unstructured as well as structured paper documents, scans, e-mail messages, and other sources for subsequent use in document management systems. The four basic data extraction operations in ABBYY FlexiCapture include classification, optical recognition, verification, and export to ERP, ECM or BPM systems.
ABBYY FlexiCapture is capable of handling the full range of data processing needs, from small-scale projects to distributed industrial capture of large volumes of data, providing high levels of security and reliability expected from enterprise-grade software solutions.
The basic document processing scenario is as follows:
- Documents are placed in the automatic scanner feeder and scanning begins. Images can also be imported from email or a mobile device, etc.
- Scanned document images are submitted for recognition, at which point the software automatically identifies documents, including multipage documents, locates meaningful fields, extracts data and loads check rules.
- After the recognition has been completed the extracted data undergoes an automatic check rules. If necessary, the process of visual check for data and rule errors is launched.
- Recognized and verified data along with electronic copies of documents are saved to a database, an information system, or a file.
ABBYY FlexiCapture has two different installation types:
The type of installation should be selected during the installation of the product. For each type of installation a different serial number is required.
Software and hardware requirements
CPU | 2 GHz or faster |
Operating system | Note. To use a localized version of ABBYY FlexiCapture, make sure your operating system supports the corresponding GUI language. |
RAM | at least 4 GB |
Disk space | 4 GB (including 2 GB for installation) |
Other requirements | - Microsoft .NET Framework 4.7.2 or later
Note. You can look up the version of your .NET Framework in the registry. Please visit this Microsoft web page for detailed instructions. - Microsoft .NET Runtime 8.0 or later
- Microsoft Office (version 2007 or later) or LibreOffice (version 4.0 or later)
- A scanner with TWAIN, WIA or ISIS support
|
Servers
CPU | Application Server: 2 GHz or faster with 2 cores Other servers: 2 GHz or faster |
Operating system | - Windows Server 2012
- Windows Server 2012 R2
- Windows Server 2016
- Windows Server 2019
- Windows Server 2022
Note. To use a localized version of ABBYY FlexiCapture, make sure your operating system supports the corresponding GUI language. |
RAM | At least 2 GB for each component Note. An additional 4 GB RAM is required if Database Server is installed. |
Disk space | - Application Server: 500 MB for installation
- Processing Server: 400 MB for installation
- Licensing Server: 100 MB for installation
- 2 GB for SQL Server database
- Additional space is required for the file storage
|
Browser (to open Administration and Monitoring Console) | - Google Chrome 55 or later (32-bit)
- Mozilla Firefox 50 or later (32-bit)
- Microsoft Edge 41 or later
Note. ABBYY FlexiCapture works best with Google Chrome and other Chromium-based browsers. - Internet Explorer 11
Note. To ensure that Internet Explorer 11 works correctly, install .NET Framework 4.7.2 on the computer with the Application Server or add the address of an application server to the list of websites that are opened in compatibility mode.
Important! Disclaimer for Internet Explorer users/Known Issue Due to the known limitations of Internet Explorer 11, you may observe the issues while processing more than 100 pages or having numerous verification tasks with ABBYY FlexiCapture. Using Internet Explorer browser for an extended period of time can cause the browser to consume a lot of the machine’s memory and slow down the client performance and eventually crash the browser. To avoid the unwanted interruptions of ABBYY FlexiCapture processing tasks ABBYY recommends you to use Microsoft Edge, Google Chrome or other browsers for the professional verification tasks. Nevertheless, ABBYY FlexiCapture web-stations are fully functioning in Internet Explorer 11, thus they should be used for ad-hoc processing preferably. Important notes for users of Internet Explorer - In the event of a verification malfunction, the operator will not be able to resume the task immediately after the session is restored. This task will become available only after the inactive sessions have been purged. By default, inactive sessions are purged every 4 hours. You can change this setting in the web.config file on the Processing Server. We do not recommend purging inactive sessions too often. The recommended minimum setting is 10 minutes.
- Starting from FlexiCapture R3 Update 1, each new task is opened in a new tab to optimize memory use. However, this also means that operators will not be able to receive new tasks automatically. To revert to the old behavior, open the web.config file for the web station and set the IEVerificationNewWindow key to false.
- In Internet Explorer 11, users will not be able to enter Japanese text using the corresponding Microsoft IME.
|
Other requirements | - The computer where the server is installed must be connected to your domain
- Video card and display with a resolution of 1024×768
- Internet Information Services 7 or higher
- Microsoft .NET Framework 4.7.2 or higher
- Microsoft .NET Runtime 8.0 or higher
- Microsoft SQL Server 2016 SP2, 2017, 2019, 2022;
Microsoft Azure; Oracle Database 12c, 18c, 19c; PostgreSQL 11 or later. Additionally, Microsoft SQL Server Native Client 2016 SP1 or later is required for creating databases. - Visual C++ 2015 Redistributable
|
Stations
CPU | 2 GHz or faster |
Operating System | - Windows 10
- Windows 11
- Windows Server 2012 + Desktop Experience
- Windows Server 2012 R2 + Desktop Experience
- Windows Server 2016 + Desktop Experience
- Windows Server 2019 + Desktop Experience
- Windows Server 2022 + Desktop Experience
Note. To use a localized version of ABBYY FlexiCapture, make sure your operating system supports the corresponding GUI language. |
RAM | Project Setup Station, Verification Station, Data Verification Station: 2 GB Processing Station: at least 2.5 GB for each CPU core Scanning Station: 1 GB |
Disk space | Scanning Station: 1 GB (including 200 MB for installation and sufficient disk space for scanned images) Other stations: 4 GB (including 2 GB for installation) |
Other requirements | - A scanner with TWAIN, WIA or ISIS support
- Video card and display with a resolution of 1024×768
- The computer where the station is installed must be connected to your domain
- Microsoft .NET Framework 4.7.2 or later
- Microsoft .NET Runtime 8.0 or later
- Microsoft Office (version 2007 or later) or LibreOffice (version 4.0 or later)
|
HTML5 Web Stations (new)
CPU | 1.6 GHz or faster |
Operating System | - Windows 10
- Windows 11
- Windows Server 2012 + Desktop Experience
- Windows Server 2012 R2 + Desktop Experience
- Windows Server 2016 + Desktop Experience
- Windows Server 2019 + Desktop Experience
- Windows Server 2022 + Desktop Experience
Note. To use a localized version of ABBYY FlexiCapture, make sure your operating system supports the corresponding GUI language. |
RAM | 1 GB |
Disk space | - Sufficient space to install a browser
- At least 100 MB for program operation
- An additional 560 MB is required to install the ABBYY Scanning Plugin for the Web Scanning Station
|
Browser | - Google Chrome 55 or later (32-bit)
Security settings for Google Chrome:
- JavaScript = Allow all sites
- plugins = Run automatically
Note. All plugins are disabled by default. To enable a plugin, open chrome://plugins/ in the browser and select the Always allowed option for the desired plugin.
- Mozilla Firefox 50 or later (32-bit)
Security settings for Mozilla Firefox:
- Java scripting = Enable
- Firefox will remember history (Options → Privacy)
- Microsoft Edge 41 or later
Security settings for Microsoft Edge:
- JavaScript = Allow all sites
- plugins = Run automatically
Note. ABBYY FlexiCapture works best with Google Chrome and other Chromium-based browsers. - Microsoft Internet Explorer 11
Browser security settings: Internet Explorer medium-high protection level. Detailed required settings for Internet Explorer:
- Run ActiveX controls and plugins = Enable
- Script ActiveX controls marked safe for scripting = Enable
- Active scripting = Enable
Note. To ensure that Internet Explorer 11 works correctly, install .NET Framework 4.7.2 on the computer with the Application Server or add the address of an application server to the list of websites that are opened in compatibility mode. Note. The Metro-style version of Internet Explorer 10 that comes with Windows 8 is not supported.
Important! Disclaimer for Internet Explorer users/Known Issue Due to the known limitations of Internet Explorer 11, you may observe the issues while processing more than 100 pages or having numerous verification tasks with ABBYY FlexiCapture. Using Internet Explorer browser for an extended period of time can cause the browser to consume a lot of the machine’s memory and slow down the client performance and eventually crash the browser. To avoid the unwanted interruptions of ABBYY FlexiCapture processing tasks ABBYY recommends you to use Microsoft Edge, Google Chrome or other browsers for the professional verification tasks. Nevertheless, ABBYY FlexiCapture web-stations are fully functioning in Internet Explorer 11, thus they should be used for ad-hoc processing preferably. Important notes for users of Internet Explorer - In the event of a verification malfunction, the operator will not be able to resume the task immediately after the session is restored. This task will become available only after the inactive sessions have been purged. By default, inactive sessions are purged every 4 hours. You can change this setting in the web.config file on the Processing Server. We do not recommend purging inactive sessions too often. The recommended minimum setting is 10 minutes.
- Starting from FlexiCapture R3 Update 1, each new task is opened in a new tab to optimize memory use. However, this also means that operators will not be able to receive new tasks automatically. To revert to the old behavior, open the web.config file for the web station and set the IEVerificationNewWindow key to false.
- In Internet Explorer 11, users will not be able to enter Japanese text using the corresponding Microsoft IME.
|
Other requirements | - Video card and display with a resolution of 1024×768
- For Web Scanning Station:
- A scanner supporting the TWAIN interface. WIA scanners can be accessed from the station but they may not operate properly
- ABBYY Scanning Plugin (see below)
|
ABBYY Scanning Plugin
To ensure the correct operation of the Web Scanning Station, you must install the ABBYY Scanning Plugin.The table below lists the operating systems on which the ABBYY Scanning Plugin can be installed with various permissions:ABBYY Scanning Plugin |
|---|
OS | Permissions | UAC | EXE |
Windows Server 2012* | Administrator | Recommended | V |
No | V |
User | Recommended | X |
No | X |
Windows Server 2012 R2 | Administrator | Recommended | V |
No | V |
User | Recommended | X |
No | X |
Windows 10 | Administrator | Recommended | V |
No | V |
User | Recommended | V |
No | V |
Windows 11 | Administrator | Recommended | V |
No | V |
User | Recommended | V |
No | V |
To allow the ABBYY Scanning Plugin to be installed on Windows Server 2012, run the executable file Setup.exe as Administrator or change the security policy by setting the value of the registry key HKEY_LOCAL_MACHINE\Software\Policies\Microsoft\Windows\Installer DisableMSI to “0”.
For detailed instructions on how to install the ABBYY Scanning Plugin, see Web Scanning Station Help or Web Capture Station Help.Remote Verification Station
CPU | 2 GHz or faster |
Operating System | - Windows 10
- Windows 11
- Windows Server 2012 + Desktop Experience
- Windows Server 2012 R2 + Desktop Experience
- Windows Server 2016 + Desktop Experience
- Windows Server 2019 + Desktop Experience
- Windows Server 2022 + Desktop Experience
Note. To use a localized version of ABBYY FlexiCapture, make sure your operating system supports the corresponding GUI language. |
RAM | 1 GB |
Disk space | 400 MB |
Other requirements | - Video card and display with a resolution of 1024×768
- Microsoft .NET Framework 4.7.2 or later
- Microsoft .NET Runtime 8.0 or later
|
ClickOnce Scanning Station
CPU | 2 GHz or faster |
Operating System | - Windows 10
- Windows Server 11
- Windows Server 2012 + Desktop Experience
- Windows Server 2012 R2 + Desktop Experience
- Windows Server 2016 + Desktop Experience
- Windows Server 2019 + Desktop Experience
- Windows Server 2022 + Desktop Experience
Note. To use a localized version of ABBYY FlexiCapture, make sure your operating system supports the corresponding GUI language. |
RAM | 1 GB |
Disk space | 1.5 GB (including 550 MB for installation and sufficient space for scanned images). The size of downloadable file is 270 MB |
Browser | For ClickOnce deployment: - Internet Explorer 11
Note. To ensure that Internet Explorer 11 works correctly, install .NET Framework 4.7.2 on the computer with the Application Server or add the address of an application server to the list of websites that are opened in compatibility mode.
Important! Disclaimer for Internet Explorer users/Known Issue Due to the known limitations of Internet Explorer 11, you may observe the issues while processing more than 100 pages or having numerous verification tasks with ABBYY FlexiCapture. Using Internet Explorer browser for an extended period of time can cause the browser to consume a lot of the machine’s memory and slow down the client performance and eventually crash the browser. To avoid the unwanted interruptions of ABBYY FlexiCapture processing tasks ABBYY recommends you to use Microsoft Edge, Google Chrome or other browsers for the professional verification tasks. Nevertheless, ABBYY FlexiCapture web-stations are fully functioning in Internet Explorer 11, thus they should be used for ad-hoc processing preferably. Important notes for users of Internet Explorer - In the event of a verification malfunction, the operator will not be able to resume the task immediately after the session is restored. This task will become available only after the inactive sessions have been purged. By default, inactive sessions are purged every 4 hours. You can change this setting in the web.config file on the Processing Server. We do not recommend purging inactive sessions too often. The recommended minimum setting is 10 minutes.
- Starting from FlexiCapture R3 Update 1, each new task is opened in a new tab to optimize memory use. However, this also means that operators will not be able to receive new tasks automatically. To revert to the old behavior, open the web.config file for the web station and set the IEVerificationNewWindow key to false.
- In Internet Explorer 11, users will not be able to enter Japanese text using the corresponding Microsoft IME.
|
Other requirements | - A scanner with TWAIN, WIA or ISIS support
- Video card and display with a resolution of 1024×768
- Microsoft .NET Framework 4.7.2 or later
- Microsoft .NET Runtime 8.0 or later
|
Supported virtual environments
The following virtual machines are supported:
- Virtual platforms that imitate physical machines:
- VMWare Workstation (any version)
- Hyper-V (any version)
Note: Hyper-V version corresponds to the version of the operating system.
Note: Hyper-V virtual machines do not work with USB devices.
- Oracle VirtualBox (any version)
- VMWare ESXi (server included with VMWare vSphere, any version)
- Virtual platforms imitating workplaces / applications:
- VMWare Horizon 5.2.0
- Citrix XenApp 7.13
- Cloud services:
- Microsoft Azure
- Amazon Cloud
Installing the Program
- It is recommended that you close all other applications before installing the program.
- Before installing and setting up ABBYY FlexiCapture, be sure to disable UAC (User Account Control). Alternatively, you can install using the built-in administrator account.
- Place the ABBYY FlexiCapture DVD-ROM into the DVD-ROM drive.
- On the Autorun menu, select Standalone Installation and follow the instructions of the setup wizard. (If Autorun is disabled on your computer, double-click the autorun.exe file located on the DVD-ROM).
- The setup wizard will compare the locale of your system and the selected language, will check the version of your operating system and the availability of the administrative privileges. If the languages are incompatible, the version of the operating system is not supported by the program or you do not have the administrative privileges, a warning message will be displayed.
- If all the checks are successfully passed, the end-user license agreement will be displayed. Read the license agreement carefully and, if you agree with the terms of the agreement, select the corresponding option and click Next.
- In the Setup Type dialog box, select one of the available installation modes:
- Administrator Station – The Administrator Station, FormDesigner, and FlexiLayout Studio will be installed. Select this option if you need to set up ABBYY FlexiCapture to process a specific kind of document.
- Operator Station – Only the Operator Station will be installed. Select this option to start processing documents as an Operator.
- Administrator and Operator Stations (selected by default) – The Administrator Station, the Operator Station, FormDesigner, and FlexiLayout Studio will be installed. Select this option if you need to set up to set up ABBYY FlexiCapture to process a specific kind of document and start processing documents as an Operator.
- Next, select a destination folder. The program files will be copied onto your computer.
- FlexiCapture License Manager will be launched automatically so that you can activate your copy of the application. Enter your serial number and activate the application.
To install and set up the server components of ABBYY FlexiCapture, you must first install Internet Information Services (IIS), Microsoft .NET Framework, and Microsoft SQL Server.Internet Information Services (IIS) and Microsoft .NET Framework are installed via the Server Manager console (Start → All programs → Administrative Tools → Server Manager):
- In Server Manager, click Add roles and features.
- In the Server Roles list, select Web Server (IIS).
If IIS is already installed on your computer, make sure that the following IIS components are selected:Web Management Tools
-
IIS 6 Management Compatibility
- IIS Scripting Tools
- IIS 6 WMI Compatibility
- IIS Metabase and IIS 6 configuration compatibility
-
IIS Management Console
World Wide Web Services
-
Application Development Features
- .NET Extensibility
- ASP.NET
- ISAPI Extensions
- ISAPI Filters
-
Common HTTP Features
- Default Document
- HTTP Errors
- HTTP Redirection
- Static Content
-
Security
- Basic Authentication
- Request Filtering
- Windows Authentication
You can additionally install any other IIS components that you need or install IIS in its entirety.
In the Features list, select .NET Framework 4.5 Features and make sure that the following components are selected:
- .NET Framework (includes .NET 2.0 and 3.0)
- .NET Framework 4.5 Advanced Services
Microsoft SQL Server can be installed from the ABBYY FlexiCapture 12 setup package:
- Run Autorun.exe.
- Click 2. Distributed Installation → 1. Install External Components → Microsoft SQL Server 2016 SP1 Express.
- When installing Microsoft SQL Server, specify the following:
- Named instance: e.g., SQLExpress;
- Authentication Mode: Mixed Mode (SQL Server authentication and Windows authentication);
- The password for the SQL Server system administrator (sa) account and SQL Server administrators.
Installing servers
To install ABBYY FlexiCapture servers:
- On the Autorun menu, click 2. Distributed Installation → 2. Install Servers and follow the instructions of the install wizard.
- In the Custom Setup dialog box, select the following components:
- Processing Server
- Protection Server
- Application Server
Finally, specify a destination folder.Once the setup is finished, the following will be launched automatically:
- the License Manage utility, where you can activate your serial number.
- the Administration and Monitoring Console, where you can set up Application Server.
You can also launch the License Manager and the Administration and Monitoring Console manually by clicking Start → All Programs → ABBYY FlexiCapture 12 Servers.
Installing stations
To install ABBYY FlexiCapture stations:
- On the Autorun menu, click 2. Distributed Installation → 2. Install Workstations and follow the instructions of the setup wizard.
- In the Custom Setup dialog box, select the components you want to install (by default, all of the components are selected) and specify a destination folder.
- In the Protection Server Location dialog box, keep the default value (127.0.0.1).
- In the User account dialog box, select this account for the processing service: Default account (NT AUTHORITY\Network Service).
ABBYY FlexiCapture setup
To set up ABBYY FlexiCapture:
- Open the Administration and Monitoring Console under a user account that has administrative privileges. Use one of the following two methods:
- Click Start → All programs → ABBYY FlexiCapture 12 Servers → Administration and Monitoring Console
or
Click Settings → Application Server and then click the Create new database button. In the window that opens, specify the following:
Server instance name | (local)\sqlexpress Note: If SQL Server is not installed locally, the server instance name will look like this: <computer_name>\sqlexpress |
Database name | FCDemoDataBase |
Authentication settings | Database Server Authentication |
User name and Password | The name and password of the database administrator that were specified when installing Microsoft SQL Server |
Use external file storage | Select this option and specify the path to a file storage location for example: C:\FileStorage |
Click OK. Once the database is created, you will be issued a temporary password, which is the word “password.” Please open the log-in page (https://localhost/FlexiCapture12/Login) and change this password.
For detailed instructions on creating a new database, please refer to the System Administrator’s Guide.
-
Set up the Processing Server:
-
Launch the Processing Server Monitor (click Start → All Programs → ABBYY FlexiCapture 12 Servers → Processing Server).
-
On the Actions menu, click Add Server → Local Host.
-
Make sure that the Processing Server is running. Otherwise, click Actions → Start.
Note: For detailed instructions on setting up the Processing Server, please refer to System Administrator’s Guide.
-
To add Processing Stations: selecting the Stations item in the ABBYY FlexiCapture 12 Servers tree, select <Server_Name>, and then click Actions → Add Stations…. In the window that opens, click By name… and type “localhost” to add the locally installed Processing Station. Start the Processing Station (Actions → Start).
-
Upload a project to the server:
- Launch the Project Setup Station (click Start → All Programs → ABBYY FlexiCapture 12 Stations → Project Setup Station).
- Open a local project (click File → Open Project…).
Note: You can select any of the sample projects stored in this folder: %public%\ABBYY\FlexiCapture\12.0\Samples.
- Upload the project to the server (click File → Upload Project to Server…). Enter the address of the Application Server in the following format: https://localhost.
Note: If the Project Setup Station and the Application Server are installed on different computers, the server address will look like this: https://<ApplicationServer> where <ApplicationServer> is the name of the computer on which the Application Server is installed.
- Select Use server authentication and enter the name and password of the database administrator.
Note: If you are planning to demonstrate how images can be imported from Hot Folders, enable Hot Folder processing in the Administration and Monitoring Console (click Settings → Projects).
ABBYY FlexiCapture 12 is now ready for demonstration.
If you need more information on setting up ABBYY FlexiCapture 12 or if you encounter any problems when completing the steps listed on this page, please refer to the System Administrator’s Guide.
(c) ABBYY Production LLC, 2021. All rights reserved.